|
STEP
|
INSPECTION
|
ACTION
|
|
1
|
INSPECT HORN AND HAZARD WARNING LIGHT OPERATION DURING ON-BOARD DIAGNOSIS
• Did all of the following items work during on-board diagnostic function operation?
-
- Hazard lights flashed
|
Yes
|
Go to Step 4.
|
|
No
|
Go to the next step.
|
|
2
|
INSPECT HAZARD WARNING LIGHT CIRCUIT
• Do the hazard warning lights flash when the hazard warning switch is on?
|
Yes
|
Go to the next step.
|
|
No
|
Inspect hazard warning light circuit.
|
|
*3
|
CHECK TO SEE WHETHER MALFUNCTION IS IN WIRING HARNESS (BETWEEN KEYLESS UNIT AND FLASHER UNIT) OR KEYLESS UNIT
• Measure the voltage at keyless unit terminal H or short cord terminal D during on-board diagnostic function operation.
-
- When the hazard warning light flashes: Alternates between B+ and below 1.0 V
• Is the voltage as above?
|
Yes
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|
|
No
|
• Inspect the wiring harness between the keyless unit and the flasher unit.
-
- If the wiring harness is OK, replace the keyless unit and reprogram transmitter ID code, then go to Step 8.
-
- If there is wiring harness malfunction, repair the wiring harness, then go to Step 8.
|
|
4
|
MAKE SURE THAT ALL DOORS LOCK AND UNLOCK DURING ON-BOARD DIAGNOSIS
• Did all doors unlock and lock during on-board diagnostic function operation?
|
Yes
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|
|
No
|
Go to the next step.
|
|
5
|
INSPECT DOOR LOCK LINKAGE
• Operate inner door lock knob and make sure door locks and unlocks manually.
• Does every door lock system work?
|
Yes
|
Go to the next step.
|
|
No
|
Inspect the door lock linkage.
|
|
*6
|
CHECK TO SEE WHETHER MALFUNCTION IS IN DOOR LOCK ACTUATOR, DOOR LOCK TIMER UNIT GROUND CIRCUIT OR ELSEWHERE
• Measure the voltage at keyless unit terminal O or short cord terminal F during on-board diagnostic function operation.
-
- With double locking system or theft-deterrent system
-
• All door locked: 5→2.5→5 V
-
• All door unlocked: 5→below 1.0 V→5 V
-
- Other
-
• All door locked: B+→6 V→B+
-
• All door unlocked: B+→below 1.0 V→B+
• Is the voltage as above?
|
Yes
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|
|
No
|
• Inspect the door lock timer unit connector.
• Inspect the wiring harness between the keyless unit and the door lock timer unit.
-
- If above parts are OK, go to the next step.
-
- If above parts malfunction, repair malfunctioning part.
|
|
*7
|
CHECK TO SEE WHETHER MALFUNCTION IS IN KEYLESS UNIT OR DOOR LOCK TIMER UNIT
• Measure the voltage at door lock timer unit terminal F.
• Is voltage as follows?
-
- With double locking system or theft-deterrent system: 5 V
-
- Other: B+
|
Yes
|
Replace the keyless unit and reprogram transmitter ID code, then go to the next step.
|
|
No
|
Replace the door lock timer unit, then go to the next step.
|
|
8
|
RECHECK MALFUNCTION SYMPTOM AFTER REPAIR
• Does keyless entry system operate properly?
|
Yes
|
Troubleshooting completed.
Explain repairs to customer.
|
|
No
|
Recheck malfunction symptoms, then repeat from Step 1 if malfunction recurs.
|