Diagnostic procedure
|
STEP
|
INSPECTION
|
ACTION
|
|
|---|---|---|---|
|
1
|
PERFORM DTC CONFIRMATION PROCEDURE
• Perform DTC CONFIRMATION PROCEDURE.
• Is the same DTC present?
|
Yes
|
Go to the next step.
|
|
No
|
Intermittent concern exists. Go to INTERMITTENT CONCERN TROUBLESHOOTING procedure.
|
||
|
2
|
INSPECT DRIVE BELT CONDITION
• Verify that the drive belt auto tensioner indicator mark does not exceed limit.
• Is the front drive belt normal?
|
Yes
|
Go to the next step.
|
|
No
|
Replace and/or adjust the drive belt, then go to Step 9.
|
||
|
3
|
INSPECT POOR CONNECTION OF PCM CONNECTOR
• Turn the ignition switch off.
• Disconnect the PCM connector.
• Inspect for poor connection (such as damaged/pulled-out terminals, corrosion).
• Is there any malfunction?
|
Yes
|
Repair the terminals, then go to Step 9.
|
|
No
|
Go to the next step.
|
||
|
4
|
INSPECT POOR CONNECTION OF GENERATOR CONNECTOR
• Disconnect generator connector.
• Inspect for poor connection (such as damaged/pulled-out terminals, corrosion).
• Is there any malfunction?
|
Yes
|
Repair or replace the terminals, then go to Step 9.
|
|
No
|
Go to the next step.
|
||
|
5
|
INSPECT GENERATOR CONTROL CIRCUIT FOR SHORT TO GROUND
• Inspect for continuity between generator terminal D (wiring harness-side) and body ground.
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness for short to ground, then go to Step 9.
|
|
No
|
Go to the next step.
|
||
|
6
|
INSPECT GENERATOR OUTPUT VOLTAGE MONITOR CIRCUIT FOR SHORT TO GROUND
• Inspect for continuity between generator terminal P (wiring harness-side) and body ground.
• Is there continuity?
|
Yes
|
Repair or replace the wiring harness for short to ground, then go to Step 9.
|
|
No
|
Go to the next step.
|
||
|
7
|
INSPECT GENERATOR CONTROL CIRCUIT FOR OPEN
• Measure the resistance between generator terminal D (wiring harness-side) and PCM terminal 1AD (wiring harness-side).
• Is there continuity?
|
Yes
|
Go to the next step.
|
|
No
|
Repair or replace wiring harness for open circuit, then go to Step 9.
|
||
|
8
|
INSPECT GENERATOR OUTPUT VOLTAGE MONITOR CIRCUIT FOR OPEN CIRCUIT
• Measure the resistance between generator terminal P (wiring harness-side) and PCM terminal 1AA (wiring harness-side).
• Is there continuity?
|
Yes
|
Repair or replace the generator, then go to the next step.
|
|
No
|
Repair or replace the wiring harness for open circuit, then go to the next step.
|
||
|
9
|
VERIFY TROUBLESHOOTING OF DTC P2503 COMPLETED
• Make sure to reconnect all connectors.
• Clear the DTC from the PCM memory using the WDS or equivalent.
• Perform KOER self-test.
• Is the same DTC present?
|
Yes
|
Replace the PCM, then go to the next step.
|
|
No
|
Go to the next step.
|
||
|
10
|
VERIFY AFTER REPAIR PROCEDURE
• Perform "After Repair Procedure".
(See AFTER REPAIR PROCEDURE [L3].)
• Is there any DTC present?
|
Yes
|
Go to the applicable DTC inspection.
(See DTC TABLE [L3].)
|
|
No
|
Troubleshooting completed.
|
||